Objective To study the physiological indexes of children receiving cardiopulmonary exercise testing(CPET)in order to establish the normal CPET reference value in Chinese children. Methods Four hundred and fifty healthy children underwent the CPET with the standard scheme using the cardiopulmonary testing system.There were fifty children per age,and the gender ratio was 1∶1.The indexes included oxygen uptake at anaerobic threshold (VO2@AT),peak oxygen uptake (VO2 peak),peak oxygen pulse (peak VO2/HR),minimum of respiratory minute volume to CO2 production (VE/VCO2 minimum),slope of respiratory minute volume to CO2 production (VE/VCO2 slope),slope of oxygen uptake efficiency (OUES),peak tolerance power (Pmax),peak heart rate (HRmax) and maximal minute ventilation(VEmax). Results The VO2 peak of boys was:4~6 years old:(816.36±152.03)ml/min;7~9 years old:(1 132.19±261.6)ml/min;10~12 years old:(1 418.99±270.2)ml/min respectively.The VO2 peak of girls was:4~6:(700.36±139.77)ml/min;7~9 years old:(1 004.19±198.5)ml/min;10~12:(1 264.97±230.2)ml/min.VO2@AT,VO2 peak,Peak VO2/HR,OUES,Pmax and VEmax all increased with age (P<0.001).VE/VCO2 minimum and VE/VCO2 slope decreased with age(P<0.001).The prediction equations for the above indexes were established by parameters of anthropometry.Peak VO2/HR=-2.757+0.148×age (y) +0.049 × height (cm) +0.040× weight (kg) +0.892 × gender ("boys" =1,"girls" =0). Conclusions This study is to provide CPET medical reference value based on a large sample of Chinese children.The study can be used under the circumstances that there is no pediatric medical reference of CPET in China.
Key words
cardiopulmonary exercise testing /
children /
physiological index /
medical reference values
{{custom_sec.title}}
{{custom_sec.title}}
{{custom_sec.content}}
References
[1] Weisman IM,Beck KC,Casaburi R,et al.ATS/ACCP statement on cardiopulmonary exercise testing [J].Am J Respir Crit Care Med,2003,167:211-377.
[2] Kipps AK,Graham DA,Harrild DM,et al.Longitudinal exercise capacity of patients with repaired tetralogy of fallot[J].Am J Cardiol,2012,108:99-105.
[3] Goldberg DJ,Avitabile CM,McBride MG,et al.Exercise capacity in the Fontan circulation[J].Cardiol Young,2013,23:823-829.
[4] Massin MM.The role of exercise testing in pediatric cardiology[J].Arch Cardiovasc Dis,2014,107(5):319-327.
[5] Cordina RL,O'Meagher S,Karmali A,et al.Resistance training improves cardiac output,exercise capacity and tolerance to positive airway pressure in Fontan physiology[J].Int J Cardiol,2013,168:780-788.
[6] Samuel B,Jade B.A systematic review of reference values in pediatric cardiopulmonary exercise testing[J].Pediatr Cardiol,2015,36(8):1553-1564.
[7] 相婷,杨巧芝.健康儿童128例心肺运动试验生理指标分析[J].中华实用儿科临床杂志,2015,12(30):1805-1808.
[8] Lee Jun-Sook,Jang So-lck,Kim Seong-Ho,et al.The results of cardiopulmonary exercise test in healthy Korean children and adolescent:single center study[J].Korean J Pediatr,2013,56(6):242-246.
[9] Bongers BC,de Vries SI,Obeid J,et al.The steep ramp test in dutch white children and adolescents:age-and sex-related normative values[J].Phys Ther,2013,93(11):1530-1539.
[10] Ten Harkel ADJ,Takken T,Van Osch-Gevers M,et al.Normal values for cardiopulmonary exercise testing in children[J].Eur J Cardiovasc Prev Rehabil,2011,18(1):48-54.
[11] Cooper DM,Weiler-Ravell D.Gas exchange response to exercise in children[J].Am Rev Respir Dis,1984,129(Suppl1):47-48.